09/10 EINS 512427
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THIS APPLIANCE
REMEMBER: when replacing a part on this appliance, use only spare parts that
you can be assured conform to the safety and performance specification that we
require. Do not use reconditioned or copy parts that have not been clearly
authorised by AGA.
For use in GB and IE
Installation
Instructions
GC 3
(THREE OVEN)
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - (THREE OVEN)

09/10 EINS 512427PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THIS APPLIANCEREMEMBER: when replacing a part on this appliance, use only spare part

Page 2 - CONTENTS

10COMMISSIONING (CONTINUED)LIGHTING THE BURNER - FIG. 2.CAUTION: NO SMOKING OR NAKED LIGHTSOpen the outer burner door to expose the gas control combin

Page 3 - HEALTH & SAFETY

9. Check burner pressure as follows:-Repeat instructions 8 on completely cold cooker with the pressure gauge fitted to the burner pressure test point

Page 4 - LOCATION

12For further advice or information contactyour local AGA SpecialistWithAGA’s policy of continuous productimprovement, the Company reserves the right

Page 5

SECTION PAGEHEALTH & SAFETY 3INSTALLATION 4LOCATION 4TECHNICAL DATA - 3 OVEN AGA (GC3) ONLY 5TECHNICAL DATA - 3 OVEN AGA WITH MODULE (GC3M) 6TECHN

Page 6 - DESN 512449

Consumer ProtectionAs responsible manufacturers we take care to make sure that our products are designed andconstructed to meet the required safety st

Page 7 - TECHNICAL DATA (CONTINUED)

With specific exceptions, the installing of any type of AGA cooker is subject to the respectivedirections contained in current issue of The Building R

Page 8 - BAKING OVEN BAFFLE PLATE

5TECHNICAL DATA - 3 OVEN AGA (GC3) ONLYFIG. 1 DESN 512841 BABCDE FGHJKLMNPWmm987889 851 679 4671035411330756112573 39 3 698 116PLEASE NOTE: SIDE CLEAR

Page 9 - COMMISSIONING

TECHNICAL DATA - 3 OVEN AGA WITH MODULE (GC3M)FIG. 1A - GAS SUPPLY CONNECTIONS (APPROXIMATE POSITIONS)NOTE: 1/4” BSP to 15mm fitting provided.DESN 512

Page 10 - COMMISSIONING (CONTINUED)

NATURAL G20MAXIMUM HEAT INPUT 5kWThermostat Bypass 100 or 120Main Burner Injector 400Pilot Injector 4212Inlet Pressure 20mbarBurner Pressure 10mbarPRO

Page 11 - INSTRUCTIONS

The following notes are intended to give general guidance:-The initial length of flue pipe from the appliance flue socket should be vertical for at le

Page 12

COMMISSIONING9DESN 512431FIG. 2FIG. 3FIG. AFIG. BFIG. CFIG. D(6)(2)(3)(5)(4)(1)