WARNING: THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE IS DESIGNED FOR THE VOLTAGE STATED ON THE RATING PLATE, WHICH IS SITUATED
BEHIND THE LOWER CONTROL PANEL DOOR.
A 13 amp 230v ~ 50 Hz fused electrical supply is required adjacent to the appliance. External wiring to the unit must be
installed using a 3 core heat resistant 180ºC Rated sheathed cable and in accordance with the current wiring regulations
and any local regulations which apply.
The method of connection to the mains electricity supply must facilitate complete electrical isolation of the appliance,
preferably by a fused double pole switch, having a contact separation of at least 3mm in both poles. We strongly
recommend connection via a fused double pole switch for integrity of the connection.
NOTE: Switched spur outlet should only serve the appliance.
The isolator should not be positioned immediately above the cooker, but must be fitted within 2 metres of the appliance.
ELECTRICAL
5
BAKING OVEN BAFFLE PLATE
A metal plate which is provided in the AGA pack MUST be positioned on the top runners of the Baking Oven. Slide the
plate in fully, until it makes contact with the back of the oven.
This baffle is a permanent part of the Baking Oven, to regulate the oven temperature.
MAINS CABLE AND GUIDE TUBE ASSEMBLY
Fig. 2 DESN 514243 A/ DESN 514626